Vue de la page 0
I
1.0 PREFACE--------------------------------------------------------------------------- 1
2.0 IMPORTANT INSTRUCTIONS------------------------------------------------ 1
2.1 THE DT210 SCROLLING MENU SYSTEM ------------------------------------------------- 1
2.2 INITIALIZE SYSTEM----------------------------------------------------------------------------- 2
3.0 CONFIGURE THE DT210 ------------------------------------------------------ 2
3.1 CONFIGURE STANDARD PARAMETERS ------------------------------------------------- 2
CONFIGURE STANDARD PARAMETERS WORKSHEET ---------------------------------------------------------4
3.1.0 SET CLOCK-------------------------------------------------------------------------------------------- 5
3.1.1 & 3.1.2 CONFIGURE SERIAL PORT 1 and PORT 2 --------------------------------------- 6
3.1.3 CONFIGURE SCALE -------------------------------------------------------------------------------- 7
3.1.4 CONFIGURE PRINTER----------------------------------------------------------------------------- 9
THE CUSTOM PRINTER INTERFACE TABLE. ------------------------------------------------------------------- 10
3.1.5 CONFIGURE PASSWORD ---------------------------------------------------------------------- 11
3.1.0 PRINT DT210 CFG--------------------------------------------------------------------------------- 11
3.2 CONFIGURE PAGE PRINTER ----------------------------------------------------------------12
THE PAGE CONFIGURATION PROCEDURE -------------------------------------------------------------------- 13
3.2.1 PAGE CONFIGURATION EXAMPLE---------------------------------------------------------- 13
EXAMPLE ITEM LIST ------------------------------------------------------------------------------------------------- 13
EXAMPLE TICKET ---------------------------------------------------------------------------------------------------- 13
EXAMPLE WORK SHEET -------------------------------------------------------------------------------------------- 14
3.2.2 PAGE WORKSHEET ------------------------------------------------------------------------------- 15
4.0 DT210 STANDARD FEATURES --------------------------------------------16
4.1 CONTROL KEYS---------------------------------------------------------------------------------- 17
4.2 FIXED FUNCTION KEYS----------------------------------------------------------------------- 18
4.2.1 LAMP TEST ----------------------------------------------------------------------------------------- 18
4.2.2 CLEAR MEMORY---------------------------------------------------------------------------------- 19
4.2.3 CONFIGURE----------------------------------------------------------------------------------------- 19
4.2.4 TIME--------------------------------------------------------------------------------------------------- 19
4.2.5 DATE--------------------------------------------------------------------------------------------------- 19
4.2.6 PRINT-------------------------------------------------------------------------------------------------- 20
4.2.7 PAPER FEED---------------------------------------------------------------------------------------- 20
4.2.8 DECIMAL POINT ----------------------------------------------------------------------------------- 20
4.3 SCALE INTERFACE -----------------------------------------------------------------------------20
4.4 PRINTER INTERFACE--------------------------------------------------------------------------21
4.5 SELF TEST ------------------------------------------------------------------------------------------ 21
Vue de la page 0
1 2 3 4 5 6 ... 33 34

Résumé du contenu

Page 1

I1.0 PREFACE--------------------------------------------------------------------------- 1 2.0 IMPORTANT INSTRUCTIONS------------------------

Page 2

8 The DT210 prompts: "MOTION TIME XX" where XX is the time between motion detect samples (tenths of seconds). Press ENTER to use th

Page 3 - 1.0 PREFACE

93.1.4 CONFIGURE PRINTER Activate the CONFIGURE menu and press the ENTER key when the DT210 displays 'CONFIG PRINTER'. The DT210 disp

Page 4 - 2.2 INITIALIZE SYSTEM

10 PRINTER TYPE ADD LF TO CR PAGE PAUSE LINE LEN END OF PRINT SIZE 1 SIZE 2 SIZE 3 SIZE 4 IDS 310 N N 80 0C

Page 5

113.1.5 CONFIGURE PASSWORD There are 2 password levels. Password level 1 protects access to the ID functions and the clear memory functions.

Page 6 - SETTING

123.2 CONFIGURE PAGE PRINTER Activate the CONFIGURE menu and press the ENTER key when the DT210 displays 'CONFIG PAGE'. The DT210 pro

Page 7

13 THE PAGE CONFIGURATION PROCEDURE 1. Use the PAGE WORKSHEET provided section 3.2.2. Enter your ticket format into the worksheet using

Page 8

14EXAMPLE WORK SHEET LINE_NO COLUMN ITEM_NO SIZE 1 1 1 1 4 8 3 1 5 8 4 1 6 8 5 1 8 4 7 1 0 0 0 0 NOTE : A z

Page 9

153.2.2 PAGE WORKSHEET LINE_NO COLUMN ITEM_NO SIZE

Page 10

164.0 DT210 STANDARD FEATURES The DT210 is easy to use yet it is able to solve many complex applications. This ease of use in the face of

Page 11

174.1 CONTROL KEYS There are 4 keys that control the operation of the DT210. Understanding the 4 keys puts you in full control of the DT210. C

Page 12

II4.5.1 TEST SCALE PORT ------------------------------------------------------------------------------ 22 4.5.2 TEST SERIAL IN2 -----------------

Page 13

184.2 FIXED FUNCTION KEYS The fixed function keys are used for various test and maintenance functions. The fixed function keys are on the second

Page 14 - 3.2 CONFIGURE PAGE PRINTER

194.2.2 CLEAR MEMORY The CLEAR MEMORY key is used to clear totals, erase id memory, initialize the DT210 system. 1. Press the CLEAR MEMORY ke

Page 15

204.2.6 PRINT The PRINT key is used to send the weight, time, and date to the printer. Press the PRINT key. The DT210 prompts: 'PRINT SC

Page 16

214.4 PRINTER INTERFACE The PRINTER INTERFACE is used to print transaction tickets and summary reports. The DT210's standard printer interfa

Page 17

224.5.1 TEST SCALE PORT Activate the SELF TEST menu and press the ENTER key when the DT210 displays 'TEST SCALE PORT'. The scale po

Page 18

234.5.2 TEST SERIAL IN2 Activate the SELF TEST menu and press the ENTER key when the DT210 displays 'TEST SERIAL IN2'. The scale port

Page 19 - 4.1 CONTROL KEYS

244.5.3 TEST SERIAL OUT1 Activate the SELF TEST menu and press the ENTER key when the DT210 displays 'TEST SERIAL OUT1'. The DT210

Page 20 - 4.2 FIXED FUNCTION KEYS

254.5.5 TEST PARALLEL Activate the SELF TEST menu and press the ENTER key when the DT210 displays 'TEST PARALLEL'. The DT210 promp

Page 21

26 4.5.8 REBUILD DATA The REBUILD function attempts to repair corrupted ID data. Use this function if the DT210 locks up when accessing ID or tra

Page 22 - 4.3 SCALE INTERFACE

275.0 TROUBLESHOOTING GUIDE 1. SCALE INPUT ERROR on Power Up. The DT210 is jumpered for Current Loop Input and no idle current

Page 23 - 4.5 SELF TEST

11.0 PREFACE The DT210 is a compact data collection terminal used in industrial weighing applications. It features the following: • An 8

Page 24

286.0 INTERFACE PORTS / WIRING LISTS The DT210 has 3 interface ports: 1. SERIAL CHANNEL 1: RS232 or CURRENT LOOP The input of C

Page 25

29 6.1 SERIAL CHANNEL 1 WIRING LIST ( 25 PIN 'D' CONNECTOR ) SIGNAL NAME PIN # #1 RS232 RXD 3 Jumper W2 IN

Page 26

306.2 SERIAL CHANNEL 2 WIRING LIST ( 25 PIN 'D' CONNECTOR ) SIGNAL PIN # #2 RS232 RXD 9 ---- Jumper W1 IN

Page 27

316.3 PARALLEL TTL WIRING LIST ( 15 PIN 'D' CONNECTOR ) SIGNAL NAME CENTRONIX PIN NO. OUTPUT 0 + Data 0 9 OUTPUT 1 + Data 1

Page 28

326.4 25 PIN 'D' CONNECTOR WIRING LIST PIN # SIGNAL NAME 1 CHASSIS GND 2 #1 RS232 TXD 3 #1 RS232 RXD 4

Page 29

2For example: the CLEAR MEMORY key presents the following menu. CLEAR TOTALS ERASE MEMORY INITIALIZE SYSTEM Press the C

Page 30

3 The standard configuration parameters for the DT210 are as follows: 3.1.0 SET CLOCK Set time and date. 3.1.1 CONFIG SER PORT1 Set

Page 31 - SIGNAL NAME

4MENU SELECTION PARAMETER DEFAULT FIELD SETTING TIME NOW SET CLOCK DATE TODAY AADDJJUUSSTT SSE

Page 32

53.1.0 SET CLOCK Activate the CONFIGURE menu and press the ENTER key when the DT210 displays 'SET CLOCK'. The DT210 prompts:

Page 33 - CENTRONIX PIN NO

63.1.1 & 3.1.2 CONFIGURE SERIAL PORT 1 and PORT 2 Activate the CONFIGURE menu and press the ENTER key when the DT210 displays 'CONFIG SE

Page 34

73.1.3 CONFIGURE SCALE Activate the CONFIGURE menu and press the ENTER key when the DT210 displays 'CONFIG SCALE'. The DT210 promp